• Home
  • Sitemap
  • View Quote/Order
  • Complete Quote/Order

CODA-PIN Contact Probes & Interfacing Components

sales@coda-systems.co.uk
technical@coda-systems.co.uk
Tel: +44 (0)1787 478678
Fax: +44 (0)1787 274194
 
       What are Test Probes?
What are Interfacing Components?

  • Interfacing Components
  • Test Products
  • General Purpose Test Probes
  • ATE Test Probes
  • ATE Technology and Support Items
  • Tools and Accessories
  • High Current Test Probes
  • Micro Test Probes
  • Detection and Switching Probes
  • Coaxial Probes
  • Bladed Test Probes
  • Extended Reach Test Probes
  • Pass Marking Unit
  • Kelvin Test Pins and Accessories
  • Kelvin Pliers
  • Kelvin Test Probes
  • Pneumatic Probing Systems
  • Standalone Bench-top Test Jigs
  • Test Jig Parts


CODA SYSTEMS LIMITED
Oak Road, Little Maplestead, Halstead,
Essex, CO9 2RT United Kingdom
Tel: +44 (0)1787 478678
Fax: +44 (0)1787 274194
Email: sales@coda-systems.co.uk

Registered in England No. 1470428


Micro Test Probes • PM1 Series • PM2 Series • PM2 'R' Series • PM3 'R' Series • PA0 Series • PA0 'R' Series • PA1 Series (Short Travel) •

Micro Test Probes

A range of micro test probes designed to allow very fine pitch testing of PCBs, substrates, semiconductors and devices, from 0.46mm to 0.76mm test centres. The PM1, PM2 and PA0 series, are of a non-replaceable design; the space saved by not having a receptacle allows testing to as small as 0.46mm centres. The fitment method is a delicate yet simple process and you can have the option of a pre-attached cable, allowing easier connection to the test jig. The PM2’R’, PM3 ’R’ & PA0’R’ series use a receptacle, giving the added advantage of probe replaceability, yet still allowing testing at a minimum spacing of 0.5mm. The receptacle has the convenient option of a pre-attached cable.
For the very fine pitch testing of semi-conductor devices and PCBs down to 0.46mm centres

PM1 Series


Non-replaceable. No receptacle. 0.46mm test centres. Drill hole size - 0.27mm-0.28mm

Specification
Full travel
1.00mm
Working travel
0.67mm
Spring force
at wkg travel
15g
Current rating DC
1 Amp
Minimum test centres
0.46mm
 


INSTALLATION
The non-replaceable microprobes feature a collar at the top of the barrel, which is used as a stop in the fitment process. Due to the minute barrel diameters and thin walls, it is imperative that the drilled hole diameter (0.27mm - 0.28mm) & straightness are very accurate. We recommend that the pre-wired option is taken as connecting a cable to these probes is an extremely delicate operation.

Usually, multi-plate fixtures containing no less than 3 plates, are used to retain large multiples of probes.

Otherwise a block of stable material which will allow reliable drilled holes is to be recommended, with the microprobe fitted wire/tail first with tweezers, with a small amount of locking compound on the side to secure it, if required.


View all products in this series

PM2 Series


Non-replaceable. No receptacle. 0.51mm test centres. Drill hole size - 0.34mm to 0.36mm.

Specification
Full travel
2.00mm
Working travel
1.33mm
Spring force
at wkg travel
48g
Current rating DC
2 AmpS
Minimum test centres
0.51mm


INSTALLATION
The non-replaceable microprobes feature a collar at the top of the barrel, which is used as a stop in the fitment process. Due to the minute barrel diameters and thin walls, it is imperative that the drilled hole diameter (0.34mm - 0.36mm) and straightness are very accurate. We recommend that the pre-wired option is taken as connecting a cable to these probes is an extremely delicate operation.

Usually, multi-plate fixtures containing no less than 3 plates, are used to retain large multiples of probes.

Otherwise a block of stable material which will allow reliable drilled holes is to be recommended, with the microprobe fitted wire/tail first with tweezers, with a small amount of locking compound on the side to secure it, if required.


View all products in this series

PM2 'R' Series


Replaceable with receptacle. 0.51mm test centres

Specification
Full travel
2.00mm
Working travel
1.33mm
Spring force
at wkg travel
48g
Current rating DC
2 Amps
Minimum test centres
0.51mm

Assembly information
Assembly information


Receptacles (shown at bottom of page) :
Mounting hole size: 0.41/0.43mm. A 0.40mm drill is recommended Drill part no. DM2R

INSTALLATION
The receptacles of the replaceable microprobes feature a collar at the top of the tube, which is used as a stop in the fitment process. Due to the minute tube diameters and thin walls, it is imperative that the drilled hole diameter & straightness are very accurate. It is recommended that the pre-wired option is taken - as connecting a cable to these receptacles is an extremely delicate operation.

Usually, multi-plate fixtures containing no less than 3 plates, are used to retain multiples of receptacles.

Otherwise a block of stable material which will allow reliable drilled holes is to be recommended, with the receptacle fitted wire/tail first with tweezers. A small amount of locking compound may be required on the barrel to secure it. Then the microprobe may be pushed into the receptacle, tail first, using the tweezers, making sure light pressure is put onto the probe's collar, not onto the fragile plunger.


View all products in this series

PM3 'R' Series


Replaceable with receptacle. 0.64mm test centres

Specification
Full travel
1.91mm
Working travel
1.27mm
Spring force
at wkg travel
30g
Current rating DC
2 AmpS
Minimum test centres
0.64mm

Assembly information
Assembly information


Receptacles (shown at bottom of page) :
Mounting hole size: 0.52/0.55mm. A 0.52mm drill is most commonly used: Drill part no. DA0

INSTALLATION
The receptacles of the replaceable microprobes feature a collar at the top of the tube, which is used as a stop in the fitment process. Due to the minute tube diameters and thin walls, it is imperative that the drilled hole diameter & straightness are very accurate. It is recommended that the pre-wired option is taken - as connecting a cable to these receptacles is an extremely delicate operation.

Usually, multi-plate fixtures containing no less than 3 plates, are used to retain multiples of receptacles.

Otherwise a block of stable material which will allow reliable drilled holes is to be recommended, with the receptacle fitted wire/tail first with tweezers. A small amount of locking compound may be required on the barrel to secure it. Then the microprobe may be pushed into the receptacle, tail first, using the tweezers, making sure light pressure is put onto the probe's collar, not onto the fragile plunger.


View all products in this series

PA0 Series


Non-replaceable. No receptacle. 0.64mm test centres

Specification
Full travel
.075" (1.91mm)
Working travel
.050" (1.27mm)
Spring force
initial
at wkg travel
0.39oz (11g)
1.39oz (39g)
Current rating DC
2 Amps
Minimum test centres
.025" (.63mm)


INSTALLATION
The top of the PAO barrel is flared making its design different to many probes. This allows a high density of probes to be "pressed" directly into the probe plate eliminating the need for a receptacle or gluing. This "press-fit" feature also permits it to be installed in a variety of probe plate thicknesses and can be replaced relatively easily. The PAO is available with or without 30" of 30 AWG insulated wire attached. It is installed into the probe plate with a probe insertion tool (part no. PITO) or a pair of tweezers. Shrink tubing can be used on alternate probes to provide strain relief in the termination and to reduce the possibility of electrical shorting.

To replace the probe, the wire is cut at the termination and the probe is then pushed out of the probe plate.


View all products in this series

PA0 'R' Series


Replaceable with receptacle. 0.76mm test centres

Specification
Full travel
.075" (1.91mm)
Working travel
.050" (1.27mm)
Spring force
initial
at wkg travel
0.39oz (11g)
1.39oz (39g)
Current rating DC
2 Amps
Minimum test centres
.030" (.76mm)

Assembly information
Assembly information



Receptacles :
Mounting hole size: 0.67/0.70mm. 0.70mm drill is most commonly used: Drill part no. DA0. RIT tool part no. TA0


View all products in this series

PA1 Series (Short Travel)


A short travel general purpose test probe for 1.27mm test centres.

Specification
Full travel
.100" (2.54mm)
Working travel
.067" (1.70mm)
Spring force
initial
at wkg travel
Light spring
0.6oz (17g)
2.8oz (71g)
Heavy spring
0.8oz (23g)
3.7oz (105g)
Current rating DC
3 Amps
Minimum test centres
.050" (1.27mm)
 
Assembly information
Assembly information


View all tipstyles and receptacles in this series