General Purpose Test Probes > Long Reach
- Recessed test targets
- Component leads whose height may vary
- Replaceable test probe by use of a receptacle
- Dual-height test fixtures
ELPA2 Series
Designed for use in dual-level fixturing where two different sets of probes with different working travels are required in the same test fixture. The long reach of this item also enables access to contacts which are otherwise inaccessible with normal length probes.
Test Probe Specification
| Full travel |
10mm (.394") |
| Working travel |
8mm (.315") |
| Spring forces |
at wkg travel |
| |
120g (4.2oz) |
| Current rating DC cont (max) |
3 Amps |
| Minimum test centres |
1.91mm (.0.75") |
How to Use
|
 |
LPA5 Series
A longer reach version of PA5, this series is ideal for functional test applications where a point might be recessed or lower than the other points. For use with the standard RA5 receptacle.
Test Probe Specification
| Full travel |
10.2mm (.40") |
| Working travel |
8mm (.28") |
| Spring force |
initial |
at wkg travel |
| |
20g |
150g |
| Current rating DC cont (max) |
4 Amps |
| Minimum test centres |
3.18mm (.125") |
Receptacle Specification
Mounting hole size: 1.7/1.75mm.
1.75mm drill is most commonly used:
Drill part no. DA3. RIT tool part no. TA3 and TA4A
How to Use
|
 |
LPA7 Series
A longer reach version of PA7, this series is ideal for functional test applications where a point might be recessed or lower than the other points. For use with the standard RA7 receptacle.
Test Probe Specification
| Full travel |
10.2mm (.40") |
| Working travel |
8mm (.28") |
| Spring forces |
initial |
at wkg travel |
| |
80g (2.82oz) |
400g (14.1oz) |
| Current rating DC cont (max) |
4 Amps |
| Test centres |
4.75mm (.18") |
How to Use
|
 |
LPA4 Series
Designed for use in dual-level fixturing where two different sets of probes with different working travels are required in the same test fixture. The long reach solves other problems of gaining access to contacts which are inaccessible with normal length probes. Use the standard RA4 series receptacles as shown in the ELPA4 Series.
Test Probe Specification
| Full travel |
10.2mm (.40") |
| Working travel |
8mm (.315") |
| Spring forces |
initial |
at wkg travel |
| |
26g (2.2oz) |
227g (8.0oz) |
| Current rating DC cont (max) |
8 Amps |
| Maximum test centres |
2.54mm (.100") |
How to Use
|
 |
ELPA4 Series
The ELPA4 series has an extra-long full travel of .492" (12.5mm) compared with the .410" (10.4mm) of the LPA4 series, and with .250"(6.35mm) of the standard PA4 series ATE probes. They will fit the standard RA4 series receptacles. Additionally the ELPA4 series probes has spring force of 8.8oz (250gm) which will help in penetrating contaminates on unclean test points.
Test Probe Specification
| Full travel |
12.5mm (.492") |
| Working travel |
9.6mm (.378") |
| Spring forces |
initial |
at wkg travel |
| |
40g (2.5oz) |
225g (8.8oz) |
| Current rating DC cont (max) |
3 Amps |
| Minimum test centres |
2.54mm (.100") |
Receptacle Specification
Mounting hole size: 1.7/1.75mm.
1.75mm drill is most commonly used:
Drill part no. DA3. RIT tool part no. TA3 and TA4A
How to Use
|
 |