Specialist Test Products >
High Current Test Probes >
Current flows of up to 35 amps for load and functional testing of power components such as semi-conductors, solenoids, loaded PCBs, bus-bars, wound components and batteries. This range shares identical dimensions and will readily intermix with the PA3 - PA7 series and the PC8 series respectively.
HD-PA3 Series
This range of probes can be used for load and functional testing of power components such as semiconductors, solenoids, loaded PCBs, bus-bars, wound components and batteries. They share identical dimensions and will readily intermix with the PA3 general purpose test probes.
Test Probe Specification
| Full travel |
4.2mm |
| Working travel |
2.9mm |
| Spring force |
initial |
at wkg travel |
'S' light spring |
37g |
79g |
'X' heavy spring |
77g |
196g |
| Operating temperature range |
|
Light spring: -55 C to +105 C |
Heavy spring: -55 C to +150 C |
| Current rating DC cont (max) |
8 Amps |
| Minimum test centres |
2.54mm |
Receptacle Specification
Mounting hole size: 1.7/1.75mm.
1.75mm drill is most commonly used:
Drill part no. DA3. RIT tool part no. TA3, TA4A
|
 |
HD-PC8 Series
This range of lower profile test probes can be used for load and functional testing of power components, wound components and batteries. The short overall length is useful in positions where space is minimal.
Test Probe Specification
| Full travel |
3.5mm |
| Working travel |
2.8mm |
| Spring force |
at wkg travel |
150g |
| Operating temp. range |
-100 C to +200 C |
| Current rating DC cont (max) |
24 Amps |
| Minimum test centres |
4.0mm (.187") |
Receptacle Specification
Mounting hole size: 3.0mm.
Drill part no. DS6
|
 |
HD-PA4 Series
This range of test probes can be used for load and functional testing of power components such as semiconductors, solenoids, loaded PCBs, bus-bars, wound components and batteries. They share identical dimensions and will readily intermix with the PA4 series general purpose probes.
Test Probe Specification
| Full travel |
6.35mm |
| Working travel |
4.24mm |
| Spring force |
initial |
at wkg travel |
24g |
114g |
| Operating temp. range |
-55 C to +150 C |
| Current rating DC cont (max) |
10 Amps |
| Minimum test centres |
2.54mm |
Receptacle Specification
Mounting hole size: 1.7/1.75mm.
1.75mm drill is most commonly used:
Drill part no. DA3/DA3A.
RIT tool part no. TA3, TA4A
|
 |
HD-PA5 Series
This range of probes can be used for load and functional testing of power components such as semiconductors, solenoids, loaded PCBs, bus-bars, wound components and batteries. They share identical dimensions and will readily intermix with the PA5 series general purpose test probes.
Test Probe Specification
| Full travel |
|
6.35mm |
| Working travel |
|
4.24mm |
| Spring force |
initial |
at wkg travel |
| - 'S' light spring |
44g |
126g |
| - 'X' heavy spring (where shown) |
71g |
164g |
| Operating temp. range |
-55 C to +150 C |
| Current rating DC cont (max) |
|
15 Amps |
| Minimum test centres |
|
3.18mm |
Receptacle Specification
Mounting hole size: 2.39/2.44mm
2.4mm drill is most commonly used:
Drill part no. DA5
RIT tool part no. TA5, TA5V-220
|
 |
HD-PA6 Series
This range of test probes can be used for load and functional testing of power components such as semiconductors, solenoids, loaded PCBs, bus-bars, wound components and batteries. They share identical dimensions and will readily intermix with the PA6 series general purpose test probes.
Test Probe Specification
| Full travel |
6.35mm |
| Working travel |
4.24mm |
| Spring force |
initial |
at wkg travel |
24g |
136g |
| Operating temp. range |
-55 C to +150 C |
| Current rating DC cont (max) |
25 Amps |
| Minimum test centres |
4.75mm |
Receptacle Specification
Mounting hole size: 2.72/2.77mm.
2.75mm drill is most commonly used:
Drill part no. DA6.
RIT tool part no. TA6
|
 |
HD-PA7 Series
A slightly larger version of the HD-PA6 series, with a heavier spring force. This range of test probes can be used for load and functional testing of power components such as semiconductors, solenoids, loaded PCBs, bus-bars, wound components and batteries. They share identical dimensions and will readily intermix with the PA7 series general purpose test probes.
Test Probe Specification
| Full travel |
6.35mm |
| Working travel |
4.24mm |
| Spring force |
initial |
at wkg travel |
107g |
454g |
| Operating temp. range |
-55 C to +150 C |
| Current rating DC cont (max) |
35 Amps |
| Minimum test centres |
4.75mm (.187") |
Receptacle Specification
Mounting hole size: 3.58/3.63mm.
3.6mm drill is most commonly used:
Drill part no. DA7.
RIT tool part no. TA7
|
 |
