Pass Marking Unit
Scriber Specification
Full market tip traveltravel |
1.57mm |
Working travel |
1.27mm |
Direction of rotation |
CCW |
Scribed diameter |
1.27mm |
Mounting hole size |
11.89/11.91mm |
Plunger tip |
Carbide steel |
Receptacle |
Stainless steel |
Current rating |
50mA |
Voltage required |
12-15VDC |
Recommended duty cycle |
On |
Off |
|
1 second |
5 seconds |
Spares/Accessories
Receptacle insertion tool |
RIT-BMP |
Receptacle extraction tool |
EXT-BMP |
Spare receptacle |
BMR-1 |
Replacement carbide tip |
BMT-1 |
|
 |
Miscellaneous Tools
Wrap/strip/unwrapping hand tools
Two versatile tools which make attaching a wire onto wirewrap receptacles easy. These tools will strip the
wire and wrap it neatly as well as unwrapping any wiring that needs to be altered. WHT26M is suitable for the larger 26 AWG and provides a 'modified' wrap. The WHT30 provides a standard wrap for the more common 30 AWG wire size.
Engineers dial calliper
A pocket-sized, low-cost dial calliper ideal for measuring probe tip diameter, receptacle height and plunger travel. Manufactured from high quality engineering grade plastic which will not scratch delicate items, this calliper is ideal for factory technicians. Capacity 100mm, metric graduations with resolution down to 0.1mm.
|
 |
Receptacle Tools
Receptacle Insertion
Receptacle Insertion Tools (RIT) are for inserting the receptacle into the hole without damage. In some ranges an adjustable tool is available which can be set to the required mounting height by use of a locking allen screw. The height required can either be set using a spare receptacle or by setting up the tool on an adjacent installed receptacle.
Series |
Test Centre |
Mounting Height |
Part No. * adjustable |
RA0 |
0.76mm |
Flush |
TA0 |
LRC1 |
1.27mm |
Flush to 7.24mm (0.285") |
TC1A* |
RA1 |
(0.050") |
Flush |
TA1 |
RA2 / LRA2 |
2mm (0.075") |
Flush |
TA2 |
RA2 |
2mm |
Flush to 3.18mm (0.125") |
TA2A* |
LRA2 |
2mm |
Flush to 5.59mm (0.220") |
TA2A* |
RA3 |
2.54mm |
Flush to 4.75mm (0.187") |
TA4A* |
RA3 , RA4 |
(0.1") |
Flush |
TA3 |
RA4 |
- |
Flush to 5.59mm (0.0220") |
TA4A* |
RA5 |
3.18mm |
Flush |
TA5 |
RA6 |
4.75mm |
Flush |
TA6 |
RA7 |
(0.187") |
Flush |
TA7 |
RC1 |
2.54mm |
0.127mm (0.005") |
TC1 |
Receptacle Removal Kits
For the removal of A.T.E. receptacles which are either worn or broken. Three kits are available to make a once difficult job very easy. A separate kit is required for each standard test centre spacing. Each kit contains a tool to initially set the receptacle flush and another tool to punch the receptacle all the way through the hole. Standard Coda-Pin receptacle insertion tools are required to install the new receptacle.
Test Centre |
Receptacle Series |
Part No. |
0.1" (2.54mm) |
RA4 |
RRTRA4 |
0.075" (1.91mm) |
LRA2 |
RRTLRA2 |
0.050" (1.27mm) |
LRC1 |
RRTLRC1 |
Tungsten carbide drill bits
Ideal for drilling holes for receptacle or probe installation. Suitable for most materials the standard flute length is 10mm. A few of the sizes have an option of longer flute length for thicker probe plate material.
Please contact us for any other sizes.
Series |
Flute Diameter (mm) |
Flute Length (mm) |
Part No. |
PA0 |
0.55 |
7.0 |
DA0 |
PA0S |
0.70 |
7.0< |
DA0R |
RA1 |
0.90 |
9.8 |
DA1 |
RA2, LRA2 |
1.40 |
10.5 |
DA2 |
RA3, RA4, RC1 |
1.70 |
10.5 |
DA3 |
RA3, RA4, RC1 |
1.75 |
10.5 |
DA3A |
PA5, PD7 |
2.40 |
10.5 |
DA5 |
RA6 |
2.75 |
10.5 |
DA6 |
RA7 |
3.60 |
12.3 |
DA7 |
LRC1 |
0.97 |
9.8 |
DRC1 |
RS3, RD1 |
2.00 |
10.5 |
DS3 |
RS6, RC8 |
3.00 |
10.5 |
DS6 |
IPP1 |
1.45 |
10.5 |
DI3 |
IPG1 / IPZ1 / IPF1 |
1.40 |
10.5 |
DI1 |
IPP2 |
2.15 |
10.5 |
DI2 |
RD3 |
3.50 |
12.3 |
DD3 |
PE3 |
6.40 |
12.3 |
DE3 |
RC4 |
5.60 |
12.3 |
DC4 |
LRC1 |
0.95 |
16.0 |
DRC1L |
LRA2 |
1.40 |
16.0 |
DA2L |
RA4 |
1.70 |
16.0 |
DA3L |
Shank =3.175mm (3/8") OAL = 38mm |
|
 |
Probe Tools
Probe removal hooks
For the removal of headed probes in the LPA2, ELPA2, PA4, LPA4 and ELPA4 series from crowded test fixtures. Only for head sizes 1.2 to 2.0mm.
Probe insertion tools
These PIT's allow the installation of certain series of test probes into their receptacles with less risk of damage by handling.
|
 |
Insulated Head Probes
Insulated head probes are used for circuit board component lead detection and testing. The insulating tip is raised slightly higher than the metal serrated tip. During test, if the component lead or connector pin is set correctly, the electrical contact will be made. Pins absent or misaligned will cause the insulator to make contact
first and fail the test.
How to Use
|
 |
ATE Travel Indicator Probes
A useful series of devices for measuring the travel at any probe position in a test fixture. After the PCB is fully down onto the probe field, the indicator probes remain compressed. The change in length indicates the travel. Do not insert into the receptacle by pressing on the plunger!.
|
 |